1.
Chinese Critical Care Medicine ; (12): 110-111, 2020.
Article in Chinese | WPRIM | ID: wpr-866759

ABSTRACT

Multifunctional monitors including electrocardiograph monitor, oxygen saturation monitor, blood pressure monitor, temperature monitor, arterial pressure monitor are often used for critically ill patients in hospitals. Each function monitoring part is equipped with multiple data monitoring wires. Due to the disorderly distribution, monitoring wires are often intertwined with each other. The medical staff will spend much time for careful identification and energy in emergency use and the improper operation of the equipment leads to its damage, which could affect data monitoring result, delay the diagnosis and treatment, and cause certain medical risks. In addition, the data line is often exposed to the external environment, which has a certain impact on its service life. Moreover, the distribution of the data line is disorderly, affecting the hospital environment and appearance. Thus, a kind of medical wire storage box was designed, which could realize the monitoring data cables in proper storage and neat distribution, reducing the workload of medical staff. The wire storage box has won the National Utility Model Patent of China (ZL 2017 2 1826195.0). The introduction goes as following. The storage box includes upper box body, lower box body and winding roller. The receptacle on the upper box body and the lower box body cooperate to form a cylindrical receptacle chamber for the winding roller. The side wall of the winding roller is designed with spiral winding groove which could help wrap the excessively long wires in the winding groove for storage. When multiple boxes need to be used simultaneously, the strip and slot on both sides of the lower box are used to splice the cable boxes together which improves the uniformity with less space use. The medical storage box is easy to make and can effectively avoid line friction and damage, prolong the line service life, and save department cost. In addition, it avoids the involvement between the lines, and improves the work efficiency. It also helps to keep the department environment tidy, which complies with "6S" management requirements, with good clinical application value.

2.
Chinese Critical Care Medicine ; (12): 771-776, 2018.
Article in Chinese | WPRIM | ID: wpr-703713

ABSTRACT

Objective To observe the effects of insulin caliper for blood glucose control on glycemic central tendency, fluctuation and incidence of hypoglycemia, etc., in emergent and critical patients to evaluate its application value.Methods A prospective single-blinded randomized parallel controlled intervention study was conducted. One hundred patients with severe hyperglycemia requiring treatment with insulin infusion admitted to emergency department and intensive care unit (ICU) of the First Hospital of Jiaxing from November 2015 to November 2017 were enrolled, and they were divided into the caliper group (used patented product insulin calipers for blood glucose control to adjust insulin dose for blood glucose control) and the conventional group (used paper-based insulin dose modification scheme to adjust insulin dose for blood glucose control) on average by random number table, 50 in each group. The gender, age, acute physiology and chronic health evaluation Ⅱ(APACHEⅡ), sequential organ failure assessment (SOFA), the principal diseases, main factors affecting blood glucose (hepatic and renal insufficiency, hypoglycemic drugs, glucocorticoids, mechanical ventilation, enteral nutrition, parenteral nutrition, intravenous glucose use, etc.), blood glucose levels at each time node (once every 2 hours after insulin use and once every 4 hours after 16-72 hours), glycemic coefficient of variance (CV), glycemic lability index (GLUGLI) and mean amplitude of glycemic excursion (GLUMAGE), insulin dose, incidence of hypoglycemia, proportion of achieving the glucose control target at each time point, the length of ICU stay and hospitalization cost per patient were recorded and compared between the two groups.Results After excluding those with incomplete data and withdraw in the midway, 92 patients were enrolled in the analysis finally,47 in caliper group and 45 in conventional group. There were no significant differences in the incidence of the gender, age, APACHEⅡ, SOFA, presence of infection at admission, previous diabetes history, glycosylated hemoglobin level, blood glucose at admission, proportion of patients after surgery, major diseases at admission and major factors affecting blood glucose between the two groups. A total of 1379 blood glucose measurements were obtained in the caliper group and 1332 blood glucose measurements were obtained in the conventional group. The glycemic measurements in caliper group were significantly lower than that in conventional group at each time point from 6-72 hours. Compared with conventional group, GLUGLI and GLUMAGE were significantly decreased in the caliper group [GLUGLI: 12.96 (8.73, 19.58) vs. 23.27 (13.07, 44.61), GLUMAGE (mmol/L): 0.66±0.22 vs. 0.87±0.28, bothP< 0.01]; there was a tendency towards decreasing incidence of hypoglycemia in the caliper group [8.51% (4/47) vs. 15.56% (7/45)], but no statistical difference was found (P > 0.05); the proportion of achieving the glucose control target was significantly increased in the caliper group [41.99% (579/1379) vs. 27.18% (362/1332),P < 0.01]. There were no significant differences in glycemic CV, insulin dose, proportion of hypoglycemic measurements in total measurements, and the length of ICU stay, the length of hospital stay, incidence of nosocomial infection, patient prognosis and cost between the two groups.Conclusion For emergent and critical patients, insulin caliper for blood glucose control presents favorable application value for achieving glucose control target, reducing glycemic fluctuation, and lowering the incidence of hypoglycemia.Clinical trial registration China clinical trial registration center, ChiCTR1800015024

3.
Chinese Critical Care Medicine ; (12): 16-20, 2017.
Article in Chinese | WPRIM | ID: wpr-510561

ABSTRACT

Objective To investigate the efficiency of closed tracheal suction system (CTSS) using novel splash-proof ventilator circuit component on ventilator-associated pneumonia (VAP) and the colonization of multiple-drug resistant bacteria (MDR) in patients undergoing mechanical ventilation (MV) prevention.Methods A prospective single-blinded randomized parallel controlled intervention study was conducted. 330 severe patients admitted to the intensive care unit (ICU) of the First Hospital of Jiaxing from January 2014 to May 2016 were enrolled, and they were divided into open tracheal suction group, closed tracheal suction group, and splash-proof suction group on average by random number table. The patients in the three groups used conventional ventilator circuit component, conventional CTSS, and CTSS with a novel splash-proof ventilatorcircuit component for MV and sputum suction, respectively. The incidence of VAP, airway bacterial colonization rate, MDR and fungi colonization rate, duration of MV, length of ICU and hospitalization stay, and financial expenditure during hospitalization, as well as the in-hospital prognosis were recorded.Results After excluding patients who did not meet the inclusion criteria, incomplete data, backed out and so on, 318 patients were enrolled in the analysis finally. Compared with the open tracheal suction group, the total incidence of VAP was decreased in the closed tracheal suction group and splash-proof suction group [20.95% (22/105),21.90% (23/105) vs. 29.63% (32/108)], but no statistical difference was found (both P > 0.05), and the incidence of VAP infections/1000 MV days showed the same change tendency (cases: 14.56, 17.35 vs. 23.07). The rate of airway bacterial colonization and the rate of MDR colonization in the open tracheal suction group and splash-proof suction group were remarkably lower than those of closed tracheal suction group [32.41% (35/108), 28.57% (30/105) vs. 46.67% (49/105), 20.37% (22/108), 15.24% (16/105) vs. 39.05% (41/105)] with significantly statistical differences (allP 0.05). Compared with theclosed tracheal suction group, the duration of MV, the length of ICU and hospitalization stay were shortened in the open tracheal suction group and splash-proof suction group [duration of MV (days): 8.00 (4.00, 13.75), 8.00 (5.00, 13.00) vs. 9.00 (5.00, 16.00); the length of ICU stay (days): 10.00 (6.00, 16.00), 11.00 (7.00, 19.00) vs. 13.00 (7.50, 22.00); the length of hospitalization stay (days): 16.50 (9.25, 32.00), 19.00 (10.50, 32.50) vs. 21.00 (10.00, 36.00)], and financial expenditure during hospitalization was lowered [10 thousand Yuan: 4.95 (3.13, 8.62), 5.47 (3.84, 9.41) vs. 6.52 (3.99, 11.02)] without significantly statistical differences (allP > 0.05). Moreover, no significantly statistical difference was found in the in-hospital prognosis among the three groups.ConclusionsCTSS performed using novel splash-proof ventilator circuit component shared similar advantages in preventing VAP with the conventional CTSS. Meanwhile, it is superior because it prevented the colonization of MDR and high price in the conventional CTSS.Clinical Trail Registration Chinese Clinical Trial Registry, ChiCTR-IOR-16009694.